DEU | ENG | FRA
Log in
Sensors
Optical, Inductive, Capacitive, Ultrasonic, IR sensors, Labelsensors, Pressure, Vacuum, Pitot pressure switch, Level control, Mechanical switches, Temperature sensors
Capture values
People counting, presence detection, temperature data acquisition, humidity data acquisition, leakages, filling levels
Contactors
Contactors 2-phase, 3-phase, 4-phase, Reversing contactors
Relay
Relay, Interface modules, Special relay
High Voltage Relays
High Voltage Relays, Single Pole, Double Pole, Bi-stable
Motor circuit breaker
Motor circuit breakers, Overload relays
Lightning Surge Protection
Surge protection devices, lightning protection system, surge protection, surge arrester, surge protection adapter
Electrical Protection and Control
Circuit Breakers, Residual current breaker, Circuit breaker
Automation
Controllers, PLC, Timer, Control relays, Solid state relays, Optocouplers, Counter, Temperature controls, Transmitters, Power supplies, Displays, Motors
Operating & display
Pushbuttons, rotary switches, touch panels, bargraph displays, process displays, empty and complete housings
Climate technology
Climatic transmitters, data loggers, liquid manometers, handheld instruments, measuring probes
Distribution, wiring
Connection cables, Extension cables, Jumper cables, PVC+ cables, PUR cables, Connector, Custom cables
Ex Zone
Ex Pneumatic, Ex sensors, Ex mechanical switches, Ex terminal boxes, Ex control functions, Ex linebushings
Senior products
Old series, Discontinuation, Special parts
Information
User Online: 232
Counter: 63511368

2 Channels (AC)

Switching two phases

Crydom Halbleiterrelais Auswahlhilfe

Brand
Crydom (71)
Currrent
2x 15 A (2)
2x 25 A (32)
2x 40 A (9)
2x 50 A (28)
Control voltage
15...32 Vdc (6)
4...15 Vdc (11)
4...32 Vdc (54)
Load voltage
24...280 Vac (36)
48...530 Vac (7)
48...600 Vac (28)
Switching mode
Random Turn-On (7)
Zero Voltage Turn-On (64)
Connection
Faston terminals (17)
Screw terminal (27)
Screw terminal (27)
overvoltage protection
No (71)
LED for indication
Yes (54)
No (17)
Design:
(71)
Standard 45 x 58 mm (54)
Thermal pad incl.
Yes (2)
No (69)
71 Results
Sort by
Availability

on request
Crydom CC2425W2U
  • Locking Connector
  • Channel A top, Channel B bottom
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
97.00 CHF
on request
Crydom CC2425W2V
  • Locking Connector
  • Channel A left, Channel B right
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
97.00 CHF
on request
Crydom CC2425W2VH
  • Locking Connector
  • Channel A left, Channel B right
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
99.00 CHF
on request
Crydom CC2425W3U
  • Detachable Screw Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
97.00 CHF
on request
Crydom CC2425W3UH
  • Detachable Screw Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
99.00 CHF
on request
Crydom CC2425W3V
  • Detachable Screw Terminal
  • Channel A left, Channel B right
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
97.00 CHF
on request
Crydom CC2425W4U
  • Spring Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
101.00 CHF
on request
Crydom CC2425W4V
  • Spring Terminal
  • Channel A left, Channel B right
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
101.00 CHF
on request
Crydom CC2450W2U
  • Locking Connector
  • Channel A top, Channel B bottom
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
112.00 CHF
on request
Crydom CC2450W2V
  • Locking Connector
  • Channel A left, Channel B right
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
112.00 CHF
on request
Crydom CC2450W3U
  • Detachable Screw Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
112.00 CHF
on request
Crydom CC2450W3V
  • Detachable Screw Terminal
  • Channel A left, Channel B right
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
112.00 CHF
on request
Crydom CC2450W4U
  • Spring Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
116.00 CHF
on request
Crydom CC2450W4V
  • Spring Terminal
  • Channel A left, Channel B right
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
116.00 CHF
on request
Crydom CC4825W2U
  • Locking Connector
  • Channel A top, Channel B bottom
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
119.00 CHF
on request
Crydom CC4825W3U
  • Detachable Screw Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
119.00 CHF
on request
Crydom CC4825W3V
  • Detachable Screw Terminal
  • Channel A left, Channel B right
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
119.00 CHF
on request
Crydom CC4825W3VH
  • Detachable Screw Terminal
  • Channel A left, Channel B right
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
121.00 CHF
on request
Crydom CC4825W4U
  • Spring Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
123.00 CHF
on request
Crydom CC4825W4V
  • Spring Terminal
  • Channel A left, Channel B right
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
123.00 CHF
on request
Crydom CC4850W2U
  • Locking Connector
  • Channel A top, Channel B bottom
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
135.00 CHF
on request
Crydom CC4850W2V
  • Locking Connector
  • Channel A left, Channel B right
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
135.00 CHF
on request
Crydom CC4850W3U
  • Detachable Screw Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
135.00 CHF
on request
Crydom CC4850W3V
  • Detachable Screw Terminal
  • Channel A left, Channel B right
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
135.00 CHF
on request
Crydom CC4850W3VH
  • Detachable Screw Terminal
  • Channel A left, Channel B right
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
137.00 CHF
on request
Crydom CC4850W4U
  • Spring Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
139.00 CHF
on request
Crydom CC4850W4V
  • Spring Terminal
  • Channel A left, Channel B right
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
139.00 CHF
on request
Crydom CD2425W2V
  • Locking Connector
  • Channel A left, Channel B right
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
90.00 CHF
on request
Crydom CD2425W3V
  • Detachable Screw Terminal
  • Channel A left, Channel B right
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
90.00 CHF
on request
Crydom CD2425W4U
  • Spring Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
94.00 CHF
on request
Crydom CD2425W4UH
  • Spring Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
94.00 CHF
on request
Crydom CD2425W4V
  • Spring Terminal
  • Channel A left, Channel B right
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
94.00 CHF
on request
Crydom CD2450W2UH
  • Locking Connector
  • Channel A top, Channel B bottom
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
108.00 CHF
on request
Crydom CD2450W2V
  • Locking Connector
  • Channel A left, Channel B right
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
106.00 CHF
on request
Crydom CD2450W3U
  • Detachable Screw Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
106.00 CHF
on request
Crydom CD2450W3UH
  • Detachable Screw Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
108.00 CHF
on request
Crydom CD2450W3V
  • Detachable Screw Terminal
  • Channel A left, Channel B right
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
106.00 CHF
on request
Crydom CD2450W4U
  • Spring Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
110.00 CHF
on request
Crydom CD2450W4V
  • Spring Terminal
  • Channel A left, Channel B right
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
110.00 CHF
on request
Crydom CD4825W2U
  • Locking Connector
  • Channel A top, Channel B bottom
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
113.00 CHF
on request
Crydom CD4825W2V
  • Locking Connector
  • Channel A left, Channel B right
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
113.00 CHF
on request
Crydom CD4825W3V
  • Detachable Screw Terminal
  • Channel A left, Channel B right
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
113.00 CHF
on request
Crydom CD4825W3VH
  • Detachable Screw Terminal
  • Channel A left, Channel B right
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
122.00 CHF
on request
Crydom CD4825W4U
  • Spring Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
117.00 CHF
on request
Crydom CD4825W4V
  • Spring Terminal
  • Channel A left, Channel B right
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
117.00 CHF
on request
Crydom CD4825W4VH
  • Spring Terminal
  • Channel A left, Channel B right
  • Currrent 2x 25 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
119.00 CHF
on request
Crydom CD4850W2U
  • Locking Connector
  • Channel A top, Channel B bottom
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
128.00 CHF
on request
Crydom CD4850W2V
  • Locking Connector
  • Channel A left, Channel B right
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
128.00 CHF
on request
Crydom CD4850W3U
  • Detachable Screw Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
128.00 CHF
on request
Crydom CD4850W3V
  • Detachable Screw Terminal
  • Channel A left, Channel B right
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
128.00 CHF
on request
Crydom CD4850W3VH
  • Detachable Screw Terminal
  • Channel A left, Channel B right
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
131.00 CHF
on request
Crydom CD4850W4U
  • Spring Terminal
  • Channel A top, Channel B bottom
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
132.00 CHF
on request
Crydom CD4850W4V
  • Spring Terminal
  • Channel A left, Channel B right
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
132.00 CHF
on request
Crydom CD4850W4VH
  • Spring Terminal
  • Channel A left, Channel B right
  • Currrent 2x 50 A
  • Control voltage 4...32 Vdc
  • Load voltage 48...600 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Screw terminal
  • overvoltage protection No
  • LED for indication Yes
  • Design Standard 45 x 58 mm
  • Thermal pad incl. No
134.00 CHF
on request
Crydom D2425D
  • Currrent 2x 25 A
  • Control voltage 4...15 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. No
96.00 CHF
on request
Crydom D2425D-10
  • Currrent 2x 25 A
  • Control voltage 4...15 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Random Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. No
98.00 CHF
on request
Crydom D2425DE
  • Currrent 2x 25 A
  • Control voltage 15...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. No
100.00 CHF
on request
Crydom D2440D
  • Currrent 2x 40 A
  • Control voltage 4...15 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. No
109.00 CHF
on request
Crydom D2440D-10
  • Currrent 2x 40 A
  • Control voltage 4...15 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Random Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. No
111.00 CHF
on request
Crydom D2440DE
  • Currrent 2x 40 A
  • Control voltage 15...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. No
113.00 CHF
on request
Crydom D2440DE-10
  • Currrent 2x 40 A
  • Control voltage 15...32 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Random Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. No
115.00 CHF
on request
Crydom D2440DH
  • Currrent 2x 40 A
  • Control voltage 4...15 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. Yes
111.00 CHF
on request
Crydom H12D4825D
  • Currrent 2x 25 A
  • Control voltage 4...15 Vdc
  • Load voltage 48...530 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. No
122.00 CHF
on request
Crydom H12D4825DE
  • Currrent 2x 25 A
  • Control voltage 15...32 Vdc
  • Load voltage 48...530 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. No
127.00 CHF
on request
Crydom H12D4825DH-10
  • Currrent 2x 25 A
  • Control voltage 4...15 Vdc
  • Load voltage 48...530 Vac
  • Switching mode Random Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. Yes
127.00 CHF
on request
Crydom H12D4840D
  • Currrent 2x 40 A
  • Control voltage 4...15 Vdc
  • Load voltage 48...530 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. No
132.00 CHF
on request
Crydom H12D4840D-10
  • Currrent 2x 40 A
  • Control voltage 4...15 Vdc
  • Load voltage 48...530 Vac
  • Switching mode Random Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. No
136.00 CHF
on request
Crydom H12D4840DE
  • Currrent 2x 40 A
  • Control voltage 15...32 Vdc
  • Load voltage 48...530 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. No
136.00 CHF
on request
Crydom H12D4840DE-10
  • Currrent 2x 40 A
  • Control voltage 15...32 Vdc
  • Load voltage 48...530 Vac
  • Switching mode Random Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. No
138.00 CHF
on request
Crydom UPD2415DF
  • Currrent 2x 15 A
  • Control voltage 4...15 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Zero Voltage Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. No
79.00 CHF
on request
Crydom UPD2415DF-10
  • Currrent 2x 15 A
  • Control voltage 4...15 Vdc
  • Load voltage 24...280 Vac
  • Switching mode Random Turn-On
  • Connection Faston terminals
  • overvoltage protection No
  • LED for indication No
  • Thermal pad incl. No
81.00 CHF
 
 

ABOUT US

PRODUCTS SUPPORT AND SERVICE OUR PARTNER
  Company
Your requirements

Contact
Vacancies

+41 (0)56 222 38 18
mailbox@sentronic.com

LinkedIn Profil Sentronic AG
Sensors
Automation
Components
Distribution, Wiring
Ex Zone


ACTUAL
News
OEM Login Request
Call orders
More than 30 years of experience
Your requirements, our solutions
Testing units

Sensor KnowHow


Software Download

Available second source solutions
Crouzet
Panasonic
Telemecanique
Schneider Electric
Sensata Technologies
Kimo Instruments
Quintex
M-System
             
    (*) Due to worldwide resource problems, there may be deviations in the stated delivery times!